§ WPS template

AWS D1.1:2025 FCAW WPS for ASTM A992

How to draft an AWS D1.1:2025 Welding Procedure Specification for Flux-Cored Arc Welding (FCAW) on ASTM A992 Wide-Flange Structural Steel. Recommended filler: E71T-1. Below: process notes, base metal properties, prequalification path, typical parameters, and which essential variables to watch.

About FCAW (Flux-Cored Arc Welding)

Tubular flux-cored electrode with either external gas shielding (FCAW-G) or self-shielding (FCAW-S). Higher deposition rates than SMAW or GMAW. Slag covering the bead helps stability and out-of-position performance. Note: A5.36 was dropped from the 2025 Table 6.6 allowed-spec list for FCAW.

Process family: semi-auto. Suited to: high-deposition shop and field welding, out-of-position welding (fcaw-s with self-shield), and similar work.

About ASTM A992

The current standard for wide-flange (W) shapes in US steel construction. Replaced A36 as the default for W-shapes circa 2003. Yield range controlled (50-65 ksi) for predictable seismic performance.

AWS D1.1 Group (Table 6.9)
Group I
Yield (ksi)
50–65 (50 min)
Tensile (ksi)
65 min
Weldability
good

Prequalification path

ASTM A992 (Group I) is on the prequalified base metals list for FCAW per AWS D1.1:2025 Clause 5. A written WPS is still mandatory but no PQR test is required as long as every Clause 5 essential variable (joint geometry, filler, preheat, current/polarity, etc.) is met.

Preheat: Same as A572 Grade 50: 50°F to 3/4 in; 150°F from 3/4 in to 1-1/2 in; 225°F above (low-hydrogen).

Typical parameters

Starting points only. Verify against electrode manufacturer data and your PQR.

FillerE71T-1
Amperage180–280 A (0.045 in wire)
Voltage24–28 V
Travel speed8–18 ipm
Position(s) typically qualifiedAll positions (1G–4G); 5G/6G for pipe per Clause 10

Essential variables to watch (AWS D1.1:2025 Table 6.6)

If your shop is working from a PQR, these are the FCAW-specific changes that require requalification per Table 6.6. The rule engine flags every one of them with the row number, clause reference, and the actual delta.

  • Filler classification change
  • Shielding gas composition (FCAW-G)
  • Voltage > 7% change
  • Amperage > 10% change
  • Travel speed > 25% change

Where FCAW on ASTM A992 fits

  • Wide-flange columns and beams (W-shapes)
  • Special and moment-frame seismic applications
  • Composite beams
  • AISC 360 / 341 conforming structures

Start now

Draft this WPS in the next 2 minutes.

Start a 14-day Pro trial and the editor opens with this FCAW + ASTM A992 setup preselected. AI drafts every narrative section with inline citations to AWS D1.1:2025. Export as a PDF, your CWI signs.

Related WPS templates

FAQ

Does AWS D1.1:2025 prequalify FCAW on ASTM A992?

Yes — ASTM A992 is on the Clause 5 prequalified base metals list and FCAW is a Clause 5 prequalified process. You still need a written WPS but no PQR.

What filler is recommended for FCAW on ASTM A992?

E71T-1. Verify against your project specification and the consumable manufacturer's data sheet. Filler classification change is a Table 6.6 essential variable.

What preheat does ASTM A992 need?

Same as A572 Grade 50: 50°F to 3/4 in; 150°F from 3/4 in to 1-1/2 in; 225°F above (low-hydrogen).