§ WPS template

AWS D1.1:2025 FCAW WPS for ASTM A500 Grade B

How to draft an AWS D1.1:2025 Welding Procedure Specification for Flux-Cored Arc Welding (FCAW) on ASTM A500 Grade B Cold-Formed Tubular. Recommended filler: E71T-1. Below: process notes, base metal properties, prequalification path, typical parameters, and which essential variables to watch.

About FCAW (Flux-Cored Arc Welding)

Tubular flux-cored electrode with either external gas shielding (FCAW-G) or self-shielding (FCAW-S). Higher deposition rates than SMAW or GMAW. Slag covering the bead helps stability and out-of-position performance. Note: A5.36 was dropped from the 2025 Table 6.6 allowed-spec list for FCAW.

Process family: semi-auto. Suited to: high-deposition shop and field welding, out-of-position welding (fcaw-s with self-shield), and similar work.

About ASTM A500 Grade B

Cold-formed welded carbon-steel structural tubing — HSS (Hollow Structural Sections). Round, square, and rectangular cross-sections. The standard for architecturally-exposed structural steel and tube braces.

AWS D1.1 Group (Table 6.9)
Group I
Yield (ksi)
42 (round), 46 (shaped)
Tensile (ksi)
58
Weldability
good

Prequalification path

ASTM A500 Grade B (Group I) is on the prequalified base metals list for FCAW per AWS D1.1:2025 Clause 5. A written WPS is still mandatory but no PQR test is required as long as every Clause 5 essential variable (joint geometry, filler, preheat, current/polarity, etc.) is met.

Preheat: 50°F up to 3/4 in wall; rarely thicker than 5/8 in. Match to AWS D1.1 Table 5.7 for the corresponding base group.

Typical parameters

Starting points only. Verify against electrode manufacturer data and your PQR.

FillerE71T-1
Amperage180–280 A (0.045 in wire)
Voltage24–28 V
Travel speed8–18 ipm
Position(s) typically qualifiedAll positions (1G–4G); 5G/6G for pipe per Clause 10

Essential variables to watch (AWS D1.1:2025 Table 6.6)

If your shop is working from a PQR, these are the FCAW-specific changes that require requalification per Table 6.6. The rule engine flags every one of them with the row number, clause reference, and the actual delta.

  • Filler classification change
  • Shielding gas composition (FCAW-G)
  • Voltage > 7% change
  • Amperage > 10% change
  • Travel speed > 25% change

Where FCAW on ASTM A500 Grade B fits

  • HSS columns and braces
  • Architecturally exposed structural steel
  • Truss chords and webs
  • Stair stringers, handrails, lintels

Start now

Draft this WPS in the next 2 minutes.

Start a 14-day Pro trial and the editor opens with this FCAW + ASTM A500 Grade B setup preselected. AI drafts every narrative section with inline citations to AWS D1.1:2025. Export as a PDF, your CWI signs.

Related WPS templates

FAQ

Does AWS D1.1:2025 prequalify FCAW on ASTM A500 Grade B?

Yes — ASTM A500 Grade B is on the Clause 5 prequalified base metals list and FCAW is a Clause 5 prequalified process. You still need a written WPS but no PQR.

What filler is recommended for FCAW on ASTM A500 Grade B?

E71T-1. Verify against your project specification and the consumable manufacturer's data sheet. Filler classification change is a Table 6.6 essential variable.

What preheat does ASTM A500 Grade B need?

50°F up to 3/4 in wall; rarely thicker than 5/8 in. Match to AWS D1.1 Table 5.7 for the corresponding base group.