AWS D1.1:2025 FCAW WPS for ASTM A500 Grade B
How to draft an AWS D1.1:2025 Welding Procedure Specification for Flux-Cored Arc Welding (FCAW) on ASTM A500 Grade B Cold-Formed Tubular. Recommended filler: E71T-1. Below: process notes, base metal properties, prequalification path, typical parameters, and which essential variables to watch.
About FCAW (Flux-Cored Arc Welding)
Tubular flux-cored electrode with either external gas shielding (FCAW-G) or self-shielding (FCAW-S). Higher deposition rates than SMAW or GMAW. Slag covering the bead helps stability and out-of-position performance. Note: A5.36 was dropped from the 2025 Table 6.6 allowed-spec list for FCAW.
Process family: semi-auto. Suited to: high-deposition shop and field welding, out-of-position welding (fcaw-s with self-shield), and similar work.
About ASTM A500 Grade B
Cold-formed welded carbon-steel structural tubing — HSS (Hollow Structural Sections). Round, square, and rectangular cross-sections. The standard for architecturally-exposed structural steel and tube braces.
- AWS D1.1 Group (Table 6.9)
- Group I
- Yield (ksi)
- 42 (round), 46 (shaped)
- Tensile (ksi)
- 58
- Weldability
- good
Prequalification path
ASTM A500 Grade B (Group I) is on the prequalified base metals list for FCAW per AWS D1.1:2025 Clause 5. A written WPS is still mandatory but no PQR test is required as long as every Clause 5 essential variable (joint geometry, filler, preheat, current/polarity, etc.) is met.
Preheat: 50°F up to 3/4 in wall; rarely thicker than 5/8 in. Match to AWS D1.1 Table 5.7 for the corresponding base group.
Typical parameters
Starting points only. Verify against electrode manufacturer data and your PQR.
| Filler | E71T-1 |
| Amperage | 180–280 A (0.045 in wire) |
| Voltage | 24–28 V |
| Travel speed | 8–18 ipm |
| Position(s) typically qualified | All positions (1G–4G); 5G/6G for pipe per Clause 10 |
Essential variables to watch (AWS D1.1:2025 Table 6.6)
If your shop is working from a PQR, these are the FCAW-specific changes that require requalification per Table 6.6. The rule engine flags every one of them with the row number, clause reference, and the actual delta.
- Filler classification change
- Shielding gas composition (FCAW-G)
- Voltage > 7% change
- Amperage > 10% change
- Travel speed > 25% change
Where FCAW on ASTM A500 Grade B fits
- HSS columns and braces
- Architecturally exposed structural steel
- Truss chords and webs
- Stair stringers, handrails, lintels
Start now
Draft this WPS in the next 2 minutes.
Start a 14-day Pro trial and the editor opens with this FCAW + ASTM A500 Grade B setup preselected. AI drafts every narrative section with inline citations to AWS D1.1:2025. Export as a PDF, your CWI signs.
Related WPS templates
FAQ
Does AWS D1.1:2025 prequalify FCAW on ASTM A500 Grade B?
Yes — ASTM A500 Grade B is on the Clause 5 prequalified base metals list and FCAW is a Clause 5 prequalified process. You still need a written WPS but no PQR.
What filler is recommended for FCAW on ASTM A500 Grade B?
E71T-1. Verify against your project specification and the consumable manufacturer's data sheet. Filler classification change is a Table 6.6 essential variable.
What preheat does ASTM A500 Grade B need?
50°F up to 3/4 in wall; rarely thicker than 5/8 in. Match to AWS D1.1 Table 5.7 for the corresponding base group.