§ WPS template

AWS D1.1:2025 FCAW WPS for ASTM A36

How to draft an AWS D1.1:2025 Welding Procedure Specification for Flux-Cored Arc Welding (FCAW) on ASTM A36 Carbon Structural Steel. Recommended filler: E71T-1. Below: process notes, base metal properties, prequalification path, typical parameters, and which essential variables to watch.

About FCAW (Flux-Cored Arc Welding)

Tubular flux-cored electrode with either external gas shielding (FCAW-G) or self-shielding (FCAW-S). Higher deposition rates than SMAW or GMAW. Slag covering the bead helps stability and out-of-position performance. Note: A5.36 was dropped from the 2025 Table 6.6 allowed-spec list for FCAW.

Process family: semi-auto. Suited to: high-deposition shop and field welding, out-of-position welding (fcaw-s with self-shield), and similar work.

About ASTM A36

The default structural carbon steel for non-critical applications. Carbon content typically 0.25-0.29%, low carbon equivalent, excellent weldability with both low-hydrogen and non-low-hydrogen consumables. Plate, bar, and shapes.

AWS D1.1 Group (Table 6.9)
Group I
Yield (ksi)
36
Tensile (ksi)
58–80
Weldability
excellent

Prequalification path

ASTM A36 (Group I) is on the prequalified base metals list for FCAW per AWS D1.1:2025 Clause 5. A written WPS is still mandatory but no PQR test is required as long as every Clause 5 essential variable (joint geometry, filler, preheat, current/polarity, etc.) is met.

Preheat: No preheat required for thicknesses ≤ 3/4 in at typical heat inputs; 50°F minimum below 3/4 in, 150°F at 1-1/2 in and above per Table 5.7.

Typical parameters

Starting points only. Verify against electrode manufacturer data and your PQR.

FillerE71T-1
Amperage180–280 A (0.045 in wire)
Voltage24–28 V
Travel speed8–18 ipm
Position(s) typically qualifiedAll positions (1G–4G); 5G/6G for pipe per Clause 10

Essential variables to watch (AWS D1.1:2025 Table 6.6)

If your shop is working from a PQR, these are the FCAW-specific changes that require requalification per Table 6.6. The rule engine flags every one of them with the row number, clause reference, and the actual delta.

  • Filler classification change
  • Shielding gas composition (FCAW-G)
  • Voltage > 7% change
  • Amperage > 10% change
  • Travel speed > 25% change

Where FCAW on ASTM A36 fits

  • Light to medium structural framing
  • Miscellaneous and ornamental steel
  • Base plates and gussets
  • Non-load-critical components

Start now

Draft this WPS in the next 2 minutes.

Start a 14-day Pro trial and the editor opens with this FCAW + ASTM A36 setup preselected. AI drafts every narrative section with inline citations to AWS D1.1:2025. Export as a PDF, your CWI signs.

Related WPS templates

FAQ

Does AWS D1.1:2025 prequalify FCAW on ASTM A36?

Yes — ASTM A36 is on the Clause 5 prequalified base metals list and FCAW is a Clause 5 prequalified process. You still need a written WPS but no PQR.

What filler is recommended for FCAW on ASTM A36?

E71T-1. Verify against your project specification and the consumable manufacturer's data sheet. Filler classification change is a Table 6.6 essential variable.

What preheat does ASTM A36 need?

No preheat required for thicknesses ≤ 3/4 in at typical heat inputs; 50°F minimum below 3/4 in, 150°F at 1-1/2 in and above per Table 5.7.