§ WPS template

AWS D1.1:2025 GTAW WPS for ASTM A992

How to draft an AWS D1.1:2025 Welding Procedure Specification for Gas Tungsten Arc Welding (GTAW) on ASTM A992 Wide-Flange Structural Steel. Recommended filler: ER70S-6. Below: process notes, base metal properties, prequalification path, typical parameters, and which essential variables to watch.

About GTAW (Gas Tungsten Arc Welding)

Non-consumable tungsten electrode with separate filler rod (manual or hot/cold wire feed for mechanized GTAW). Argon or Ar/He shielding. The cleanest, most controllable arc — used for critical root passes and precision work where weld appearance and reliability matter more than deposition rate.

Process family: manual. Suited to: root passes on critical joints (then filled with another process), thin material precision welds, and similar work.

About ASTM A992

The current standard for wide-flange (W) shapes in US steel construction. Replaced A36 as the default for W-shapes circa 2003. Yield range controlled (50-65 ksi) for predictable seismic performance.

AWS D1.1 Group (Table 6.9)
Group I
Yield (ksi)
50–65 (50 min)
Tensile (ksi)
65 min
Weldability
good

Prequalification path

ASTM A992 (Group I) with GTAW requires PQR qualification per Clause 6 — GTAW is one of the processes listed in 6.15.1 as always requiring qualification. You must run a PQR test and qualify against Tables 6.6 (PQR essential variables) and, for notch-toughness applications, Table 6.8.

Preheat: Same as A572 Grade 50: 50°F to 3/4 in; 150°F from 3/4 in to 1-1/2 in; 225°F above (low-hydrogen).

Typical parameters

Starting points only. Verify against electrode manufacturer data and your PQR.

FillerER70S-6
Amperage80–200 A
Voltage10–18 V
Travel speed4–10 ipm
Position(s) typically qualifiedAll positions (1G–6G)

Essential variables to watch (AWS D1.1:2025 Table 6.6)

If your shop is working from a PQR, these are the GTAW-specific changes that require requalification per Table 6.6. The rule engine flags every one of them with the row number, clause reference, and the actual delta.

  • Filler addition or deletion (autogenous ↔ filler)
  • Cold ↔ hot wire feed
  • Filler diameter > 1/16 in change
  • Amperage > 25% change
  • Preheat decrease > 100°F

Where GTAW on ASTM A992 fits

  • Wide-flange columns and beams (W-shapes)
  • Special and moment-frame seismic applications
  • Composite beams
  • AISC 360 / 341 conforming structures

Start now

Draft this WPS in the next 2 minutes.

Start a 14-day Pro trial and the editor opens with this GTAW + ASTM A992 setup preselected. AI drafts every narrative section with inline citations to AWS D1.1:2025. Export as a PDF, your CWI signs.

Related WPS templates

FAQ

Does AWS D1.1:2025 prequalify GTAW on ASTM A992?

No. ASTM A992 with GTAW requires PQR qualification per Clause 6. Run the PQR test, then qualify the WPS against Tables 6.6 + (for CVN) 6.8.

What filler is recommended for GTAW on ASTM A992?

ER70S-6. Verify against your project specification and the consumable manufacturer's data sheet. Filler classification change is a Table 6.6 essential variable.

What preheat does ASTM A992 need?

Same as A572 Grade 50: 50°F to 3/4 in; 150°F from 3/4 in to 1-1/2 in; 225°F above (low-hydrogen).